The Bio-Medical Signals and Systems Laboratory
BAUET EEE Department provides its students with adequate laboratory facilities each semester. We believe that a student cannot learn the subject matter of a course without having any hands-on experience in the laboratory. Keeping this in mind, from the very beginning, the Department of Computer Science and Engineering is trying its level best to establish eleven (11) laboratories. Every semester we are upgrading and improving our laboratories and their experiments. A brief description of Bio-Medical Signals and Systems is given below:
The Bio-Medical Signals and Systems Laboratory has various interfacing equipment to facilitate the experiments exhibiting computer control over industrial processes. It has a range of microprocessor trainer kits and trainer boards with software including a data inputs simulator and terminal.
Established Date: 14/06/23 (According to laboratory registered book)
Financed by: BAUET’s own Fund
List of Equipment(Biomedical Signals and Systems Lab)
Room No # 516 Panorama
Room Size: 21X23 =546sft Computer Capacity: 30
S.N | Name and Specification | Quantity | Operating Condition
(Good) |
1. | BSL with Amplifier model MP-36R(1 Set)
The system should be an ideal for multi-disciplinary labs where a number of different courses may share the same lab equipment. The system should come with everything needed to conduct the most widely studied responses in physiology labs, including experimental measurements of Pulse rate along with ECG, EEG, EMG, EOG, EDA, Pulse, Airflow, Respiratory Effort, Lung Volume, Reaction Time and Skin Temperature. The ULTIMATE System should include transducers suitable for human subjects. The Student Ultimate System should Include: · MP36R Data Acquisition Unit ( At least 4 Channel) with USB Cable, DC Adapter (220V/50Hz) & Cord (Euro) · Analysis Software · Photoplethysmogram (Pulse) Transducer · Multi-lead ECG Cable · Blood Pressure Cuff Transducer (on-screen gauge) · Respiratory Effort Transducer · Stethoscope · Pressure Transducer · Headphones · Human-Safe Stimulator 0-100 V · Push-button Hand Switch · Factory-calibrated Medium Airflow Transducer · Disposable Filtered Mouthpiece (10/pk) · Disposable Noseclips (10/pk) · Finger Twitch Transducer · Hand Dynamometer · Fast Response Temperature Transducer · Colored paper for Visual Stim · Laboratory Manual (English) – includes introductory physiology text, guided procedure, and data analysis. · Searchable PDF Manuals and Tutorials (Instructor’s Guide, Answer Key, etc.) Analog Inputs: · Number of Channels: At least 4 Channels · A/D Sampling Resolution: 24-bit · Signal to Noise Ratio: > 89 dB min · CMRR: 85 dB minimum. Analog Output: · Sample Rate: 100,000 samples/sec each channel · Certification: Complies with IEC 60601-1, EMC complies with IEC 60601-1-2 , CE Marked Safety: · The data acquisition unit should satisfy the Medical Safety Test Standards affiliated with IEC 60601-1. It should be designated as Class I Type BF medical equipment · EMC · The data acquisition unit should satisfy the Medical Electromagnetic Compatibility (EMC) Test Standards affiliated with IEC 60601-1-2. |
1 Set |
1 Set |
2. | Arduino Uno R3 (Original)
· ATmega328 microcontroller · Input voltage – 7-12V · 14 Digital I/O Pins (6 PWM outputs) · 6 Analog Inputs · 32k Flash Memory · 16Mhz Clock Speed
|
03 Set | 03 Set |
3. | Electronic Blood Pressure Monitor Automatic Arm BP Machine & Pulse Rate Monitoring Meter
· Digital Blood Pressure Monitoring MachineRAK289 Electronic Blood Pressure Monitor Home Health Care Arm Meter. Sphygmomanometer Heart Beat Meter Machine. Specifications of Digital Pressure Monitoring Machine:
|
1 Set | 1 Set |
4. | Raspberry Pi
4 computer complete set with argon one v2 case
· Broadcam BCM2711, Quad-core Cortex-A72 (ARM v8) 64-bit SoC @1.5 GHz · 4GB LPDDR4-3200 SDRAM · 2.4 GHz and s GHz IEEE 802.11 ac wireless network · Bluetooth 5.0 · Gigabit Ethernet · 2 micro-HDMI ports · 64GB micro memory. |
2 Set | 2 Set |
Lab Management Committee
Sl. No. | Name, Designation | Responsibility |
1. | Md. Mushfikur Rahman Khan
Dept. Electrical and Electronic Engineering Contact No:01521329766 E-Mail: mushfikur4@gmail.com |
In-Charge |
2. | Md. Shaharia Islam
Laboratory Assistant Dept. of Electrical and Electronic Engineering Contact No.01738893214 E-mail: shahariarshoyon@gmail.com |
Asst. Lab In-Charge |